Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros

Base de datos
Tipo del documento
Intervalo de año
1.
Med Clin (Engl Ed) ; 156(10): 477-484, 2021 May 21.
Artículo en Inglés | MEDLINE | ID: covidwho-1804816

RESUMEN

BACKGROUND: There is growing evidence regarding the imaging findings of coronavirus disease 2019 (COVID-19) in chest X-rays and computed tomography scans; however, their availability during this pandemic outbreak might be compromised. Currently, the role of point-of-care ultrasonography (POCUS) has yet to be explored. OBJECTIVES: To describe the POCUS findings of COVID-19 in patients with the disease admitted to the emergency department (ED), correlating them with vital signs, laboratory and radiologic results, therapeutic decisions, and the prognosis. METHODS: Prospective study performed in the ED of 2 academic hospitals. Patients with highly suspected or confirmed COVID-19 underwent a lung ultrasonography (lung POCUS), focused cardiac ultrasound (FOCUS), and inferior vena cava (IVC) exam. RESULTS: Between March and April 2020, 96 patients were enrolled. The mean age was 68.2 years (SD 17.5). The most common findings in the lung POCUS were an irregular pleural line (63.2%), bilateral confluence (55.2%), and isolated B-lines (53.1%), which were associated with a positive RT-PCR (odds ratio 4.327; 95% CI 1.216-15.401; p < .001), and correlated with IL-6 levels (rho = 0.622; p = .002). The IVC negatively correlated with levels of expiratory pO2 (rho = -0.539; p = .014) and inspiratory pO2 (rho = -0.527; p = 0.017), and expiratory diameter positively correlated with troponin I (rho = 0.509; p = .03). After the POCUS exam, almost 20% of the patients had an associated condition that required a change in their treatment or management. CONCLUSIONS: POCUS parameters have the potential to impact the diagnosis, management, and prognosis of patients with confirmed or suspected COVID-19.


ANTECEDENTES: Existe una evidencia creciente con respecto a los hallazgos por imagen de la COVID-19, tanto en radiografías de tórax como en tomografía computarizada; sin embargo, la disponibilidad de estas técnicas durante la pandemia podría verse comprometida. OBJETIVOS: Describir los hallazgos en la ecografía en el punto de atención (POCUS) en pacientes con COVID-19 que consultaron en el servicio de urgencias (SU), correlacionándolos con signos vitales, resultados analíticos y radiológicos, decisiones terapéuticas y pronóstico. MÉTODOS: Estudio prospectivo realizado en los SU de dos hospitales académicos. Los pacientes con COVID-19 con alta sospecha o confirmada se sometieron a una ecografía pulmonar (POCUS pulmonar), una ecocardioscopia y una ecografía de la vena cava inferior (VCI). RESULTADOS: Entre marzo y abril del 2020, se reclutaron 96 pacientes. La edad media fue de 68,2 años (DE 17,5). Los hallazgos más comunes en el POCUS pulmonar fueron la línea pleural irregular (63,2%), las líneas B confluyentes bilateral (55,2%) y aisladas (53,1%), que se vincularon con una RT-PCR (odds ratio 4,327; IC 95% 1,216 a 15,401; p < 0,001), y se asoció con los niveles de interleucina-6 (IL-6) (ρ = 0,622; p = 0,002). La VCI se correlacionó negativamente con los niveles de pO2 espiratorio (ρ = − 0,539; p = 0,014) y pO2 inspiratorio (ρ = − 0,527; p = 0,017), y el diámetro espiratorio se relacionó positivamente con la troponina I (ρ = 0,509; p = 0, 03). Después del examen POCUS, casi el 20% de los pacientes tenían una condición asociada que requería un cambio en el tratamiento o manejo previo. CONCLUSIONES: Los parámetros POCUS tienen el potencial de afectar el diagnóstico, manejo y pronóstico de pacientes con sospecha o confirmación de COVID-19.

2.
J Ultrasound ; 25(3): 483-491, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: covidwho-1544611

RESUMEN

BACKGROUND: In the past months, several lung ultrasonography (LUS) protocols have been proposed, mainly on previously validated schemes independent of coronavirus disease 2019 (COVID-19). OBJECTIVES: The main purpose of this study was to determine the impact and accuracy of different LUS protocols proposed in COVID-19. METHODS: Patients were evaluated with a standard sequence of LUS scans in 72 intercostal spaces along 14 anatomic lines in the chest. A scoring system of LUS findings was reported and then analyzed separately according to each proposed LUS protocol zones. This score was then correlated to a validated Pulmonary Inflammation Index (PII) on chest Computed Tomography (CT). RESULTS: Thirty-two patients were enrolled. The most frequent pattern was ground-glass opacities in the chest X-ray (53.1%), chest CT (59.1%) and subpleural or lobar consolidations (40.8%) in the posteroinferior areas (p < 0.001) on LUS. The Interclass Correlation Coefficient (ICC) was significantly correlated with almost every protocol analyzed except the 8-zone (p = 0.119) and the 10-zone protocol that only included one posterior point (p = 0.052). The highest ICC was obtained with a 12-zone protocol (ICC 0.500; p = 0.027) and decreased as more points were included. CONCLUSIONS: In conclusion, our study results suggest that performing an ultrasound protocol with 12-zone scanning, including the superior and inferior areas of the anterior, lateral and posterior regions of the chest was consistent with higher ICC and higher degree of concordance with CT. We emphasize the need of a more standardization technique to further implement and develop this imaging modality in COVID-19.


Asunto(s)
COVID-19 , COVID-19/diagnóstico por imagen , Humanos , Pulmón/diagnóstico por imagen , SARS-CoV-2 , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía/métodos
3.
Med Clin (Barc) ; 156(10): 477-484, 2021 05 21.
Artículo en Inglés, Español | MEDLINE | ID: covidwho-1051839

RESUMEN

BACKGROUND: There is growing evidence regarding the imaging findings of coronavirus disease 2019 (COVID-19) in chest X-rays and computed tomography scans; however, their availability during this pandemic outbreak might be compromised. Currently, the role of point-of-care ultrasonography (POCUS) has yet to be explored. OBJECTIVES: To describe the POCUS findings of COVID-19 in patients with the disease admitted to the emergency department (ED), correlating them with vital signs, laboratory and radiologic results, therapeutic decisions, and the prognosis. METHODS: Prospective study performed in the ED of 2 academic hospitals. Patients with highly suspected or confirmed COVID-19 underwent a lung ultrasonography (lung POCUS), focused cardiac ultrasound (FOCUS), and inferior vena cava (IVC) exam. RESULTS: Between March and April 2020, 96 patients were enrolled. The mean age was 68.2 years (SD 17.5). The most common findings in the lung POCUS were an irregular pleural line (63.2%), bilateral confluence (55.2%), and isolated B-lines (53.1%), which were associated with a positive RT-PCR (odds ratio 4.327; 95% CI 1.216-15.401; p<.001), and correlated with IL-6 levels (rho=0.622; p=.002). The IVC negatively correlated with levels of expiratory pO2 (rho=-0.539; p=.014) and inspiratory pO2 (rho=-0.527; p=0.017), and expiratory diameter positively correlated with troponin I (rho=0.509; p=.03). After the POCUS exam, almost 20% of the patients had an associated condition that required a change in their treatment or management. CONCLUSIONS: POCUS parameters have the potential to impact the diagnosis, management, and prognosis of patients with confirmed or suspected COVID-19.


Asunto(s)
COVID-19 , Sistemas de Atención de Punto , Anciano , Humanos , Pulmón/diagnóstico por imagen , Estudios Prospectivos , SARS-CoV-2 , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA